Level 1 vs Level 2, Unit by Unit

Price the Whole Building

By sending, you agree Madden Chimney Experts may contact you by call, automated text or email about your request. Consent isn't required to buy. Msg & data rates may apply; reply STOP to opt out. Privacy Policy

Snow-covered rooftop with a brick chimney

A building rarely needs one level throughout

Owners booking chimney work for a whole building often ask for "the full inspection" on every fireplace, on the theory that more is safer. Sometimes it is. More often, most units need the visual level and one or two need the camera. Choosing per unit keeps the bill honest and puts the deeper look where something has actually changed.

This post compares the two levels as they apply to Los Angeles buildings with several fireplaces, and shows how Madden Chimney Experts decides between them, unit by unit.

What each level reaches

The levels come from NFPA 211. It defines three; the third involves opening walls or masonry and is rare enough that we leave it aside here.

Level 1, $56 per fireplace. Everything a light and a ladder can reach with nothing taken apart: the firebox and its walls, the damper and how it moves, the lower part of the flue, the hearth, the space to the mantel and, outside, the chimney top, its cap and the roof around it. On a gas unit we add the burner area, the glass and the vent termination. The question it answers: is this fireplace fit for the same use it has had?

Level 2, $405 per fireplace. All of the above, plus a recording camera through the inside of the flue from the damper to the top, and a look in the attic, crawl space or any reachable space the chimney runs through. The question it answers: is the passage the smoke takes still whole over its entire length?

Side by side, for a building

Level 1Level 2
Price per fireplace$56$405
Inside of the flueAs far as a light showsFull height, on video
Attic and crawl spaceNot includedIncluded where reachable
SuitsYearly records, steady useSales, changes, damage, a Level 1 concern
Usual share of a buildingMost unitsA few units

Events that move one unit up

A fireplace earns the camera when something about it has changed or is unknown. In a building, those events hit one unit at a time:

  • The unit changes hands. A condo sale, or the sale of the whole building. A buyer has no way to know how that flue was used.
  • Turnover after a long tenancy. The standard does not demand it, but many managers move a unit up when a tenant who burned a lot of wood moves out.
  • A change of fuel or appliance. Wood to gas, an open fireplace to an insert, or a new gas log set.
  • Smoke, soot or odor complaints. A tenant who smells smoke from the unit next door may be describing a crack between two flues.
  • Shaking. After a strong quake, brick stacks in this region have cracked inside while looking fine from the street. The 1994 quake is the one most Los Angeles owners still talk about.
  • A chimney fire, even a short one that burned out on its own.
  • A Level 1 finding we cannot judge without seeing more of the flue.

A unit with none of these stays at Level 1. The record shows the level and the reason, so whoever reads it next year knows why unit 2 got the camera and unit 5 did not.

Shared stacks change the arithmetic

Older brick buildings often run two or three flues side by side in one stack. A crack in the wall between two flues lets smoke from one fireplace into another unit. When one flue in a shared stack gets a Level 2 because of a complaint, we often suggest the camera for its neighbor too, because the shared wall is the evidence. We put that suggestion in writing and you decide.

The same logic runs the other way. If the camera shows a sound divider and whole tiles in the flue we were sent to, the neighboring flue can stay at Level 1, and its record notes that the shared wall was seen from the other side.

Getting the mix right for your building

The deciding facts are your unit list and what has happened in each unit since the last visit. Enter the unit list in the form above, with any sales, turnovers or complaints, and we call back with a suggested level for each fireplace and the total.

What both levels produce

Either level ends in the same kind of record: the fireplace identified by unit and room, the date, the level, photos, findings in plain words and a verdict. A Level 2 record adds stills from the flue video, each marked with roughly where along the flue it was taken. Repairs, if any, come on a separate estimate. We cover Los Angeles and nearby Bell Gardens, Downey and San Gabriel, at the same per-fireplace prices.

For the cost side, see chimney inspection cost per unit. For a sale, see chimney reports in a home sale.

Owners' questions

What if a Level 1 turns up a reason for the camera? The record names the unit, the finding and why the camera is warranted, and we schedule the Level 2 with your approval.

Does a gas fireplace ever need Level 2? Yes, in the same situations: a sale, a change of appliance, or signs of venting trouble such as soot on the glass or a smell in the room.

Is a Level 2 needed every year? No. NFPA 211 asks for a yearly inspection; the event list above decides which level.

Can units on one stack get different levels? Yes. Each flue is its own passage. The shared-wall case above is the one time we suggest looking at a neighbor as well.

To find out which level each of your fireplaces needs, write to us from our contact page with the building address and anything that has changed since the last visit.

Responsible for More Than One Fireplace?

Madden Chimney Experts quotes buildings unit by unit and writes up a page for every chimney, so owners, boards and managers in Los Angeles and nearby cities can see each home on its own.

Call (323) 524-5515